+ /* Gameblabla - Tightening the timings (as taken from Duckstation).
+ * The timings from Duckstation are based upon hardware tests.
+ * Mednafen's timing don't work for Gundam Battle Assault 2 in PAL/50hz mode,
+ * seems to be timing sensitive as it can depend on the CPU's clock speed.
+ * */
+ if (cdr.DriveState != DRIVESTATE_STANDBY)
+ {
+ delay = 7000;
+ }
+ else
+ {
+ delay = (((cdr.Mode & MODE_SPEED) ? 2 : 1) * (1000000));
+ CDRMISC_INT((cdr.Mode & MODE_SPEED) ? cdReadTime / 2 : cdReadTime);
+ }
+ AddIrqQueue(CdlPause + 0x100, delay);